High-precision detection of fluid and air pressure


CE , UKCA Approved
Features
Allows high-precision fluid pressure management
The analog voltage output of the sensor head can achieve a high-precision sensing of ±1 % F.S. (at a normal temperature of 23 ℃ 73.4 ℉).
Compact stainless body
Compact size of HEX. 22 × 59 mm 0.866 × 2.323 in (excluding the screws). The body is also stainless so it can be used in various environments.

Oil-less single-layer diaphragm
Oil is not encapsulated in the diaphragm of the pressure sensing portion. No need to worry that oil will leak into the medium when the sensor head is damaged.

Strong against pressure surges from throttle loading
Controls pressure surges and reduces sensor failure.

Product line

The dual display means that the “current value” and the “threshold value”, it makes direct setting of threshold value
Equipped with a 30 mm 1.181 in square compact-sized dual display. Because the current value and the threshold value can be checked at the same time, the threshold value can be set and checked smoothly without having to switch screen modes. ON/OFF operations are still carried out while the threshold values are being set, so setting to the same sensitivity as dial control-type sensors is possible. And naturally a key lock function is also equipped.

3-color display (Red, Green, Orange)
The main display changes color in line with changes in the status of output ON/OFF operation, and it also changes color while setting is in progress. The sensor status can therefore be understood easily, and operating errors can be reduced.

Equipped with new functions optimal for fluid pressure
Equipped with functions optimal for fluid pressure management while inheriting the operability of the DP-100 series.
• Peak / Bottom hold (output-linked)
When output turns on (or off), the controller’s digital display (current value) is reset and peak / bottom hold operation starts. For example, this functionality could be used to verify the peak pressure for an industrial press each time a workpiece is loaded.
• Current value hold
The controller’s digital display (current value) is held while external input is on. By activating external input the moment you wish to capture the pressure value, you can pause and verify the display.
MOUNTING
Tight installation to panels is possible
An exclusive mounting bracket MS-DP1-2 that is suitable for 1 to 6 mm 0.039 to 0.236 in panel thickness is available.

Order guide
Product Configuration

Sensor heads
| Type | Appearance | Rated pressure range | Model No. | Pressure port | Applicable fluid |
|---|---|---|---|---|---|
| Compound pressure | ![]() |
-0.1 to +1.0 MPa | DPH-L113V | R1/4 male thread | Gases and fluids that do not corrode stainless steel SUS304, SUS630, or SUSXM7 |
| Positive pressure | 0 to +1.0 MPa | DPH-L113 | |||
| 0 to +3.5 MPa | DPH-L133 | ||||
| 0 to +10 MPa | DPH-L114 | ||||
| 0 to +50 MPa | DPH-L154 |
Controllers
| Appearance | Model No. | Comparative output |
|---|---|---|
![]() * CN-66A-C2(Connector attached cable 2 m 6.562 ft) is attached. |
DPC-L101 | NPN open-collector transistor |
| DPC-L101-P | PNP open-collector transistor |
Type without connector attached cable
Type without connector attached cable is available. When ordering this type, suffix “-J” to the Model No.
(e.g) Type without connector attached cable of DPC-L101-P is “DPC-L101-P-J”.
Accessory
・CN-66A-C2 (Connector attached cable 2 m 6.562 ft)