Communication Unit for Digital Displacement Sensors SC-HG1

Connect Fiber Sensors and Displacement
Sensors to CC-Link IE Field for High-Speed Control

Communication unit
for EtherCAT
SC-HG1-ETC

Communication unit
for CC-Link IE Field
SC-HG1-CEF

Communication unit
for CC-Link
SC-HG1-C

Communication unit
for RS-485
SC-HG1-485

CE Approved

December 2019 Compatible with self-monitoring function.
  • EtherCAT communication unit SC-HG1-ETC : Compatible
  • CC-Link IE Field communication unit SC-HG1-CEF : Units shipped in and after December 2019 are compatible.
  • CC-Link communication unit SC-HG1-C : Units manufactured in and after December 2019 are compatible.
  • RS-485 communication unit SC-HG1-485 : Units manufactured on and after November 18, 2019 are compatible.
Features
Direct Connection to High-Speed EtherCAT [SC-HG1-ETC]

Acquires various numeric data from thru-beam type digital displacement sensor HG-T series and contact-type digital displacement sensor HG-S series and allows change of their settings.

  • Connects HG-T / HG-S series digital displacement sensors directly to EtherCAT!
  • Enables change of various settings all at once.
  • Allows switching of controller’s internal banks.
  • Obtains high-accuracy measurement data without a program.

* EtherCAT® is a registered trademark patent-protected technology, licensed by Beckhoff Automation GmbH of Germany.

Direct Connection to CC-Link Master
Direct transfer of high-precision measurement values in the order of 0.1 μm 0.004 mil [SC-HG1-C]

Direct connection to CC-Link
Program-less transmission of high-precision data
Batch change of internal settings via CC-Link
CC-Link Communication Unit SC-HG1-C

* When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit

Please refer to “Communication Unit for CC-Link IE Field / CC-Link” for details of SC-HG1-C and SC-HG1-CEF.
For use of high-precision measurement results as traceability data [SC-HG1-485]

Transfers not only measurements results obtained at multiple points but also setting statuses as digital data in a batch!
Provides powerful support to the management of inspection records and identification of failure causes.

* When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit.

USB-based PC setting software
HG-T Configuration Tool

When the USB-based PC setting software, “HG-T Configuration Tool,” is used together with the USB communication unit SC-HG1-USB or RS-485 communication unit SC-HG1-485, current values and settings in the HG-T series can be confirmed and changed using a PC.

Order guide
Product name Model No. Description
EtherCAT
Communication
Unit
SC-HG1-ETC Can directly send high-accuracy measurement values to EtherCAT Master.
• Communication protocol: EtherCAT
• Number of connectable controllers for HG-T / HG-S series Controller: Up to 15 units (1 master unit, 14 slave units) per SC-HG1-ETC unit
CC-Link IE Field
communication unit
SC-HG1-CEF Can directly send high-precision measurement values to a CC-Link IE Field host device.
• Communication method
CC-Link IE Field
• Number of connected units
Host (CC-Link IE Field): Max. 121 units (1 master station, 120 slave stations)
Controllers: Maximum of 15 units (1 master, 14 slaves) per SC-HG1-CEF unit
CC-Link
Communication
Unit
SC-HG1-C Can directly send high-precision measurement values to CC-Link Master.
• Communication method
Switchable CC-Link Ver.1.10 or 2.00
• Number of occupied station
CC-Link Ver.1.10: 4 stations, CC-Link Ver.2.00: Switchable 2 or 4 stations
• Number of connected units
Controllers: Maximum of 15 units (1 master, 14 slaves) per SC-HG1-C unit
RS-485
Communication
Unit
SC-HG1-485 Can directly send high-precision measurement values by RS-485 communication
• Communication protocol
MODBUS (RTU / ASCII) / MEWTOCOL-COM
• Number of connected units
Host (RS-485): 1 to 99 units when MODBUS (RTU / ASCII) is used, 1 to 64 units
when MEWTOCOL-COM is used
Controllers: Maximum of 15 units (1 master, 14 slaves) per SC-HG1-485 unit